COMPLEX RATE
COEFFICIENTS
| KFPAN : |
|---|
| K0 | = 2.70D-28*(TEMP/298)@-7.1*M
|
| KI | = 1.21D-11*(TEMP/298)@0.9
|
| FC | = 0.3
|
| KBPAN : |
|---|
| K0 | = 4.90D-03*EXP(-12100/TEMP)*M
|
| KI | = 3.7D+16*EXP(-13600/TEMP)
|
| FC | = 0.3 ;
|
| KMT01 : |
|---|
| K0 | = 1.00D-31*(TEMP/300)@-1.6*M
|
| KI | = 3.00D-11*(TEMP/300)@0.3
|
| FC | = EXP(-TEMP/1850)
|
| KMT02 : |
|---|
| K0 | = 9.00D-32*(TEMP/300)@-2.0*M
|
| KI | = 2.20D-11
|
| FC | = EXP(-TEMP/1300)
|
| KMT03 : |
|---|
| K0 | = 2.70D-30*(TEMP/300)@-3.4*M
|
| KI | = 2.00D-12*(TEMP/300)@0.2
|
| FC | = (EXP(-TEMP/250) + EXP(-1050/TEMP))
|
| KMT04 : |
|---|
| K0 | = 2.20D-03*(TEMP/300)@-4.4*EXP(-11080/TEMP)*M
|
| KI | = 9.70D+14*(TEMP/300)@0.1*EXP(-11080/TEMP)
|
| FC | = (EXP(-TEMP/250) + EXP(-1050/TEMP))
|
| KMT05: | = 1 + ((0.6*M)/(2.652D+19*(273/TEMP)))
|
| KMT06: | = 1 + (1.40D-21*EXP(2200/TEMP)*H2O)
|
| KMT07 : |
|---|
| K0 | = 7.40D-31*(TEMP/300)@-2.4*M
|
| KI | = 3.20D-11
|
| FC | = 0.8
|
| KMT08 : |
|---|
| K0 | = 2.60D-30*(TEMP/300)@-2.9*M
|
| KI | = 6.00D-11
|
| FC | = 0.43
|
| KMT09 : |
|---|
| K0 | = 1.80D-31*(TEMP/300)@-3.2*M
|
| KI | = 4.70D-12
|
| FC | = 0.6
|
| KMT10 : |
|---|
| K0 = | 5.00D-06*EXP(-10000/TEMP)*M
|
| KI = | 2.60D+15*EXP(-10900/TEMP)
|
| FC | = 0.6
|
| KMT11: | = K1 + K2
|
| K1 = | 7.20D-15*EXP(785/TEMP)
|
| K2 | = (K3*M)/(1+(K3*M/K4))
|
| K3 | = 1.90D-33*EXP(725/TEMP)
|
| K4 | = 4.10D-16*EXP(1440/TEMP)
|
| KMT12 : |
|---|
| K0 | = 4.00D-31*(TEMP/300)@-3.3*M
|
| KI | = 2.00D-12
|
| FC | = 0.45
|
| KMT13 : |
|---|
| K0 | = 1.90D-30*(TEMP/298)@-4.0*M
|
| KI | = 1.00D-11*(TEMP/298)@-1.0
|
| FC | = 0.4
|
| KMT14 : |
|---|
| K0 | = 9.00D-05*EXP(-9694/TEMP)*M
|
| KI | = 1.10D+16*EXP(-10561/TEMP)
|
| FC | = 0.4
|
| KMT15 : |
|---|
| K0 | = 6.00D-29*(TEMP/298)@-4.0*M
|
| KI | = 9.00D-12*(TEMP/298)@-1.1
|
| FC | = 0.7
|
| KMT16 : |
|---|
| K0 | = 3.00D-27*(TEMP/298)@-3.0*M
|
| KI | = 2.80D-11*(TEMP/298)@-1.3
|
| FC | = 0.5
|
| KMT17 : |
|---|
| K0 | = 5.00D-30*(TEMP/298)@-1.5*M
|
| KI | = 9.40D-12*EXP(-700/TEMP)
|
| FC | = (EXP(-TEMP/580) + EXP(-2320/TEMP))
|
THESE APPLY TO THE HETEROGENEOUS CONVERSION OF NO2 TO HONO AT THE GROUND
SURFACE, A REACTION WHICH SHOULD THEREFORE ONLY TAKE PLACE IN THE LOWER LAYER